At the second 126, the DJ exceeds the threshold once again,
so the averaging before the warning has started. 30 seconds
later, the Warning lamp has been switched on because the
LEQ value was over the threshold. At that time, the cut-off time
period starts counting.
The DJ has seen the warning and has directly reduced the level,
but unfortunately a few seconds later, he pushed the volume up
again. As the result that 1 minute after, the LEQ value was
still higher than the threshold and the cut-off relay has been
activated, cutting-out the electricity on the power amplier.
ADDITIONAL FUNCTIONS WHEN USED WITH THE ARGOS
When connected to the Argos limiter, the Hera measures the
microphone signal and sends the appropriate commands to
the Argos, which can then reduce the sound pressure level if
necessary.
The Hera can also control the pink noise generator in the
Argos. Pink noise is used as a reference for calibrating the
Hera should it be necessary to take into account differences
in sound pressure level between the actual position of the
microphone and the position at which the authorities measure.
MICROPHONE DISTANCE COMPENSATION
The measurement microphone is often located where it cannot
be interfered with. Consequently there is a good chance that
the sound pressure level at the microphone will be different
from that on the dance oor, which is where the authorities take
their level measurements. To get round this problem the Hera
can calculate the difference and factor it into its measurements.
The calibration procedure is fully described in the “installer
menu” section.