User manual

UNPACK THE ARGOS
The following should be included with each ARGOS system :
1x ARGOS
1x Microphone
1x Power cord
1x This manual
INSTALLATION
The ARGOS may be rack-mounted or free-standing.
The ARGOS will accept voltages from 220 to 240 Vac, 50 / 60 Hz.
No voltage regulation setting is necessary.
As with all pieces of precision electronic equipment, follow the next rules
when using the ARGOS :
- Do not subject the equipment to shocks or vibration.
- Avoid extreme temperatures and humidity.
- Avoid use in a dusty environment.
- Allow adequate ventilation when in operation.
REPLACING THE MAINS FUSE
Unplug the mains cord.
Gently lift the lid on the right side of the mains plug. Be cautious, the fuse-holder can not be
removed. The first compartment is used for a spare fuse, the second one, nearest to the
set, contains the active fuse.
Replace the fuse according the list below :
T40mA (slow blow fuse) Wickmann 19195 for 220 / 240 Vac. (Europe)
T40mA (slow blow fuse) Bussmann S504 for 220 / 240 Vac. (Europe)
Push back the fuse-holder.
GENERAL CARE
Avoid exposing the ARGOS to a dusty or smoke-filled environment.
Clean the surfaces of the ARGOS with a dry, lint- free cloth.
Do not use spray cleaners, thinner or solvents. A mild detergent applied to a slightly
damp cloth may be used to remove stubborn stains or grease marks.
WARMUP AND CONDENSATION
If the ARGOS is brought into a warm room from a cold environment, internal condensation
may occur. Allow between 1 and 2 hours for the unit to acclimatise before putting it into oper-
ation.
8
ARGOS - USER MANUAL
8
4
Installation and precautions.
W
W
ARNING :
ARNING :
There are no user-serviceable parts inside the ARGOS.
Do not disassemble the ARGOS.
Refer to an Apex service centre for any repairs or adjustments.