Specifications
Table Of Contents
- Title Page
- Table of Contents
- List of Figures
- List of Tables
- 1 Introduction
- 2 Installation
- 3 Navigating the LCD Display Screens
- 3.1 Basic Operating Procedure
- 3.2 Starting Point: The Main LCD Touch Screen
- 3.3 LCD Display Flow Chart
- 3.4 Details of the Exciter Status Screens
- 3.4.1 System Status Screen
- 3.4.2 Transport Stream Status Screen
- 3.4.3 Adaptive Processing Board Status Screen
- 3.4.4 Digital Processing Screens
- 3.4.4.1 Modulator Board Status, Screen 1/2
- 3.4.4.2 ADC and DAC Boards Status, Screen 2/2
- 3.4.4.3 FLO FPGA Status, Summary, Screen 1/5
- 3.4.4.4 FLO FPGA, GPS & Clock Status, Screen 2/5
- 3.4.4.5 FLO FPGA, Transport Stream Status, Screen 3/5
- 3.4.4.6 FLO FPGA, SFN FIFO Status, Screen 4/5
- 3.4.4.7 FLO FPGA, MTI Status, Screen 5/5
- 3.4.5 IF & RF Processing Status Screens
- 3.4.6 System Control Status Screens
- 3.5 Built In Tests
- 3.6 Details of the System Setup Screens
- 3.7 RTAC Operating Procedures, Main Screen.
- 4 Theory of Operation
- 5 Maintenance and Troubleshooting
- 5.1 Exciter Maintenance
- 5.2 Loading Software
- 5.3 Default Settings For DIagnostics Screens
- 5.4 Typical Settings for the More Critical Exciter Setups
- 5.5 Exciter Troubleshooting Flow Charts
- 5.6 General Troubleshooting
- 5.7 System Troubleshooting
- 5.8 Exciter Troubleshooting
- 6 Parts List
- Appendix A Exciter GUI Screen Captures

APEX™ Exciter Incorporating FLO™ Technology
Navigating the LCD Display Screens Details of the System Setup Screens
Page: 3-38 888-2604-001 03/08/07
WARNING: Disconnect primary power prior to servicing.
3.6.2.1 Power Calibration
PowerCalibration.bmp
Figure 3-33 Power Calibration Screen
Power Cal (calibration) soft key on the right side of the screen in Figure 3-32 activates the
exciter RF output power calibration procedure. The power calibration is accomplished by
connecting an accurate power meter to the RF output of the exciter and pressing the blue
up or down arrows (see Figure 3-33) until the power meter reads 250 mW average power.
Then press the Accept button to implement the new calibration or press the cancel button
to return to the old calibration.
3.6.3 RTAC Setup Screen
RTACSetup.bmp
Figure 3-34 RTAC Setup Screen