Specifications
Table Of Contents
- Title Page
- Table of Contents
- List of Figures
- List of Tables
- 1 Introduction
- 2 Installation
- 3 Navigating the LCD Display Screens
- 3.1 Basic Operating Procedure
- 3.2 Starting Point: The Main LCD Touch Screen
- 3.3 LCD Display Flow Chart
- 3.4 Details of the Exciter Status Screens
- 3.4.1 System Status Screen
- 3.4.2 Transport Stream Status Screen
- 3.4.3 Adaptive Processing Board Status Screen
- 3.4.4 Digital Processing Screens
- 3.4.4.1 Modulator Board Status, Screen 1/2
- 3.4.4.2 ADC and DAC Boards Status, Screen 2/2
- 3.4.4.3 FLO FPGA Status, Summary, Screen 1/5
- 3.4.4.4 FLO FPGA, GPS & Clock Status, Screen 2/5
- 3.4.4.5 FLO FPGA, Transport Stream Status, Screen 3/5
- 3.4.4.6 FLO FPGA, SFN FIFO Status, Screen 4/5
- 3.4.4.7 FLO FPGA, MTI Status, Screen 5/5
- 3.4.5 IF & RF Processing Status Screens
- 3.4.6 System Control Status Screens
- 3.5 Built In Tests
- 3.6 Details of the System Setup Screens
- 3.7 RTAC Operating Procedures, Main Screen.
- 4 Theory of Operation
- 5 Maintenance and Troubleshooting
- 5.1 Exciter Maintenance
- 5.2 Loading Software
- 5.3 Default Settings For DIagnostics Screens
- 5.4 Typical Settings for the More Critical Exciter Setups
- 5.5 Exciter Troubleshooting Flow Charts
- 5.6 General Troubleshooting
- 5.7 System Troubleshooting
- 5.8 Exciter Troubleshooting
- 6 Parts List
- Appendix A Exciter GUI Screen Captures

APEX™ Exciter Incorporating FLO™ Technology
Navigating the LCD Display Screens Details of the Exciter Status Screens
Page: 3-28 888-2604-001 03/08/07
WARNING: Disconnect primary power prior to servicing.
• Exc Active: (Off or On) When on, this exciter is on the air.
• RF Present: (Off or On) This is an indication that the RF level at the output of the ex-
citer is above a given threshold level. The RF presence threshold is an RF output level
of approximately 5 mW.
• Board Type: (UHF or VHF) Interface configured to fit existing UHF and VHF exciter
interface connections.
• Board Rev: This is the board revision for the External I/O board.
• CPLD Rev: This is the software revision level of the CPLD in the External I/O board.
• EEPROM: (Ok or FAULT) The EEPROM is the local board memory. It stores board
specific information such as board type, board revision, CPLD revision, and other lo-
cal data.
Note
Within any of these screens, touching Home returns to the main
screen, and touching Fault brings up the Exciter Status screen.
3.4.6.2.1 External I/O Diagnostics
ExternalIODiagnostics.bmp
Figure 3-26 External I/O Diagnostics
The External I/O Diagnostics screen is shown in Figure 3-26.
Analog loopback: Choices are Enabled or Disabled. Disabled is the normal setting.
• This function loops an analog output back through an analog input channel for diag-
nostics purposes.
The last two screen entries are Analog Output A and Analog Output B. These two entries
provide a voltage for the analog loopback test mentioned above.
• Analog Output A is looped back through analog Analog 1 and 3 inputs and Analog
Output B is looped back through Analog 2 and 4 inputs, see external I/O Board screen
Figure 3-25 for the analog inputs.