Specifications
Table Of Contents
- Title Page
- Table of Contents
- List of Figures
- List of Tables
- 1 Introduction
- 2 Installation
- 3 Navigating the LCD Display Screens
- 3.1 Basic Operating Procedure
- 3.2 Starting Point: The Main LCD Touch Screen
- 3.3 LCD Display Flow Chart
- 3.4 Details of the Exciter Status Screens
- 3.4.1 System Status Screen
- 3.4.2 Transport Stream Status Screen
- 3.4.3 Adaptive Processing Board Status Screen
- 3.4.4 Digital Processing Screens
- 3.4.4.1 Modulator Board Status, Screen 1/2
- 3.4.4.2 ADC and DAC Boards Status, Screen 2/2
- 3.4.4.3 FLO FPGA Status, Summary, Screen 1/5
- 3.4.4.4 FLO FPGA, GPS & Clock Status, Screen 2/5
- 3.4.4.5 FLO FPGA, Transport Stream Status, Screen 3/5
- 3.4.4.6 FLO FPGA, SFN FIFO Status, Screen 4/5
- 3.4.4.7 FLO FPGA, MTI Status, Screen 5/5
- 3.4.5 IF & RF Processing Status Screens
- 3.4.6 System Control Status Screens
- 3.5 Built In Tests
- 3.6 Details of the System Setup Screens
- 3.7 RTAC Operating Procedures, Main Screen.
- 4 Theory of Operation
- 5 Maintenance and Troubleshooting
- 5.1 Exciter Maintenance
- 5.2 Loading Software
- 5.3 Default Settings For DIagnostics Screens
- 5.4 Typical Settings for the More Critical Exciter Setups
- 5.5 Exciter Troubleshooting Flow Charts
- 5.6 General Troubleshooting
- 5.7 System Troubleshooting
- 5.8 Exciter Troubleshooting
- 6 Parts List
- Appendix A Exciter GUI Screen Captures

APEX™ Exciter Incorporating FLO™ Technology
Installation Configuring the Exciter
Page: 2-10 888-2604-001 03/08/07
WARNING: Disconnect primary power prior to servicing.
2.6.3 Normal Settings for Diagnostic Screens
The Diagnostics screens offer tests used to diagnose exciter problems. If the diagnostic
selections are left in the wrong states, normal operation of the exciter could be impaired.
The default values for the diagnostics screens can be found in Table 5-1 on page 10.
The following is a list of the normal states of the more critical diagnostic functions and the
exciter mute.
Status > Adaptive Processing > Diagnostics
• LoopBack: None
• Test Tones: Disabled
Status > IF & RF Processing > Up Converter > Diagnostics
• Output Power AGC: Enabled
Status > IF & RF Processing > Down Converter > Diagnostics
• RF Sample Select: Automatic
• RF Sample AGC: Enabled
Status > System Control > External I/O Board > Diagnostics
• Analog Loopback: Disabled
Setup >Exciter > Exciter Setup screen> Mute soft key.
• The exciter is normally un-muted. Pressing the button will open a sub window which
will have instruction to mute or un-mute the exciter output.