Chapter 4. Subscriber Equipment Installation
To properly ground the Outdoor Unit:
1. Locate the grounding lug on the ODU, as illustrated in Figure 4-6.
2. Provide a proper grounding conductor (NEC Section 810-21) long enough to reach
from the Outdoor Unit to the earth ground.
3. Attach one end of the conductor to the lug on the ODU.
4. Connect the other end of the grounding conductor to an appropriate earth ground
using a grounding clamp.
If you install a grounding electrode separate from the power service grounding elec-
trode system, connect the separate electrode to the grounding system in accordance
with the National Electrical Code (NEC) and local electrical codes.
Figure 4-6 Location of Grounding Lug on Outdoor Unit
Grounding Lug Location
Attach Electrode to Lug
Hole for Cable Tie