User's Manual

5–3
10004880 Rev. D1
Chapter 5. The PacketWave AIM
Using the Aperto Installation Manager
The perform any of the AIM functions, use the following procedure:
1. Connect a PC with AIM software installed to the PacketWave 200 as described in
the previous sections of this chapter.
2. Double-click on the Aperto Installation Manager icon on the PC’s desktop. This will
cause the Authentication window to be displayed, as shown in Figure 5-2. Note the
buttons at the bottom of the window.
Figure 5-2 AIM Authentication Window
3. Enter the AIM password. The default is isp.
4. Click on the Next>> button at the bottom of the window. The AIM will begin com-
munications with the PacketWave 200.
NOTE: You will get an error message if the AIM cannot establish a connection to
the PacketWave 200. Verify that you are using a crossover cable, that the
PacketWave 200 is receiving power, that the computer has just one Ethernet
interface enabled, and that it is properly configured with a fixed IP address.