User's Manual Part 1
Chapter 2. Installation and Configuration
2–2
070-20000750-01 Rev A
• Install the file j2re-1_3_0_02-win.exe from the \Software\Application\Support
directory of your CD-ROM.
• Next install the Setup.exe from the \Software\Application\AdvancedIM\win32
directory.
• Connect your Indoor Unit (IDU) to your Outdoor unit (ODU) using the appropriate
RG6 and CAT-5 cabling.
• Connect your PC to the PacketWave 620 (PW620) IDU using an Ethernet cross-over
cable.
Performing the Installation
To install the PacketWave 600 series point-to-point link you should first install the Pack-
etWave 620 (PW620) and then install the PacketWave 610 (PW610). Detailed instructions
follow.
Installing the PacketWave 620 - PW620
To install the PW620 you need to perform the following steps
• Connect the PC and the PW620
• Start the Application
• Choose the Installation Mode
• Fill Out the Configuration Parameters or Accept the Default Configura-
tion Parameters
•Allow AIM to Configure the PacketWave
Connect the PC and the PW620
Connect your PC to the PW620 using an Ethernet cross-over cable. It is best to only has
one Ethernet connection on your PC. The AIM application has no way to distinguish which
Ethernet interface to use. If you have multiple Ethernet interfaces, disable all of the extra
ones.
AIM is going to calculate an address in the current subnet of the PC to give to the Packet-
Wave devices in order for it to make an IP connection. It therefore requires that the PC have
a fixed IP address; not one assigned by a DHCP server. The figure below, Figure 2-1, gives