User's Manual Part 1
1–5
070-20000750-01 Rev A
Chapter 1. Overview
4. Tighten the pole clamp bolt until the Outdoor Unit is secured in position.
Figure 1-3 Outdoor Unit Mounting Bracket
Grounding the Outdoor Unit
Grounding of the outdoor radio/antenna is an essential part of the installation process. A
proper grounding circuit is illustrated in Figure 1-4.
WARNING: Each PacketWave 600 Series Unit is required to have lightning protec-
tion. Instructions and specific example of lightning protection equip-
ment is contained in the document titled
Surge Protection for
PacketWave Products
. This document is included in the CD that shipped
with the equipment. If missing, please contact Customer Service. Failure
to follow the instructions will void your equipment warranty.
To properly ground the Outdoor Unit:
1. Locate the installed lug on the back of the Outdoor Unit. (See Figure 1-5.)
2. Provide a proper grounding conductor (NEC Section 810-21) long enough to reach
from the Outdoor Unit to the earth ground.
3. Attach one end of the conductor to the lug.