Table A-2 MSC related Alarms/Events in PM 5000
Alarm Type Alarm Message in
EMS
Cause and Description Resolution
Memory /RAM0 Space Free: LOW
/RAM0 Space Free: NOR-
MAL
This indicates if there is a
problem with the memory in
the system.
Contact Aperto
Flash /TFFS0 Space Free [Event]
/TFFS0 FS State
This indicates that the flash
has a problem.
Contact Aperto
Msc Power Change MSC Operational
MSC -<No> POn .....
MSC -<No> POff .....
WSC 1/Redundant MSC:
Link Ok
WSC 1/Redundant MSC:
Link Down
Indicates that MSC/WSC
Card is either inserted or
removed
Fan 1 Issue EVENT: FAN-1 ShM: ..... This indicates Fan 1 is NOT
working. Replace the Fan
card.
Contact Aperto
Fan 2 Issue EVENT: FAN-2 ShM: ..... This indicates that Fan 2
NOT working
Contact Aperto
Temperature
Change
EVENT: ROOM TEMP
CHANGE.....
EVENT: CPU TEMP
CHANGE....
Room or CPU Temperature is
either above or below accept
-
able levels
FTP Download Fail-
ure
CPE Name: <name>, CPE
Mac Addr:
0xAA:0xBB:0xCC:0xDD:0x
EE:0xFF , CPE Id: <Id>:
Cfg File Not Found
CPE Name: <name>, CPE
Mac Addr:
0xAA:0xBB:0xCC:0xDD:0x
EE:0xFF , CPE Id: <Id>:
CPE CFG File download
failed
MSC Cfg File Download
Success
MSC Cfg File Download
Failure
System is not able to down-
load configuration files from
the TFTP server.
Check network topol-