User's Manual
6–25070-20000340-01 Rev A
CHAPTER 6. BSU AND S UBSCRIBER CONFIGURATION
Configuring Subscriber System Parameters
Click on the System tab so that the screen illustrated in Figure6-12 is displayed.
Specify subscriber system parameters as indicated in Table6-L.
Table6-L CPE — System Parameters
Parameter Range
(and Default)
Comments
Channel Center Frequency N/A Read-only field identifying the center frequency
established when the subscriber equipment was
initialized.
Network Access Yes or No
(Yes)
Specify whether the subscriber will be allowed on
the network. This field may be set to No to essen-
tially disable subscriber equipment.
System Location Up to 79 characters
(no default)
Enter text identifying the subscriber’s location.
CPE Name Up to 79 characters
(no default)
Enter a name or description of the subscriber site.
System Image File N/A Identifies the software which should be running on
the Indoor Unit. If different software is running, the
subscriber Indoor Unit will attempt to download the
specified software from the TFTP server.
Syslog Server IP xxx.xxx.xxx.xxx decimal
(no default)
If desired, enter the address of a syslog server
which will receive event logs directly from this sub-
scriber Indoor Unit.
User Name (no default) Enter a name for the subscriber.
MAC address 00:01:3b:xx:xx:xx
(no default)
Complete the MAC address of the subscriber Indoor
Unit as identified by a label on the unit’s rear panel.
(All Aperto MAC addresses begin with 00:01:3b.)
SMTP Server IP xxx.xxx.xxx.xxx decimal
(no default)
If desired, enter the address of a mail server which
will administer email alerts for this subscriber.
CPE Mode Bridge, Router, NAT
(Bridge)
Specify the subscriber Indoor Unit model, and
whether the unit will function as a bridge, router, or
NAT router. (If the CPE Model specified does not
match the actual unit installed, the configuration file
will be rejected when it is downloaded to the sub-
scriber Indoor Unit. In R1P1, the PacketWave 130 is
the only model supported.)
CPE Model PW110, PW120,
PW130 (PW130)
Number of Service Flows 1 to 64
(no default)
Specify the maximum number of service flows which
can be defined for this subscriber.
Encryption Not supported in R1P1.
IGMP Support Not supported in R1P1.
Max Hosts Allowed 1 to 20 Specify the maximum number of user hosts which