Spec Sheet

WT2 Wiegand Test Unit : Wiring and Use Instructions
Copyright ©2015, ASSA ABLOY Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Inc. is prohibited.
WTMN3A– PAGE 3
Notes Failure to connect the WT2 to the lock before applying power results in
false reads.
The WT2 will accept any data from a Wiegand output and any bit structure such as
the press of a key on a keypad to trigger the lock relay.
The WT2 is capable of remembering up to the last 6 learned (programmed)
cards, whether they are the same or different.
Once single card/cards are recognized, the door device will no longer
operate by the presentation of any random card until it has been reset.
To reset the device, cycle the power while holding the learn button until it
flashes three times. Any card will then activate the lock.
The system is designed to be installation-friendly with ElectroLynx
®
quick connectors.
OPERATING
INSTRUCTIONS
FOR ALL CARDS
OPERATING
INSTRUCTIONS
FOR LIMITED
To initialize the test box for all cards:
1. Connect all wires to the WT2 first.
2. Select Fail Safe or Fail Secure according to sample.
3. Select the appropriate solenoid lock voltage (12 or 24 VDC).
4. Apply power to the WT2.
5. Once the door device completes its visual and audio signaling, it will
unlock when ANY Wiegand card is presented.
To initialize the test box for a limited number of specific cards:
NUMBER OF CARDS
1. Connect all wires to the WT2 first.
2. Select Fail Safe or Fail Secure according to sample.
3. Select the appropriate solenoid lock voltage (12 or 24 VDC).
4. Apply power to the WT2.
5. Press and hold the Learn button.
6. Present a card to the lock.
7. That card is recognized and added to the list of cards that will unlock the
lock. Other cards will not work until each is presented while holding down
the learn button.
Power Input AC 100 – 240V 600mA 50Hz/60Hz
Power Output The WT2 is capable of supplying a total of 900 MA output to the unit under test.
The 900 MA is the total output for both reader interface and the lock.