WT2 Wiegand Test Unit : Wiring and Use Instructions
CONTENTS WT2, plastic, 6.25” x 3.5” x 2.375”
TEST BOX PRODUCT
DESCRIPTION
Selectors,
Switches and Visual
Monitoring
Indicators
AC / DC adapter
FOR INSTALLATION ASSISTANCE, CALL 1-800-810-WIRE
ElectroLynx cable with Molex connectors for Integrated Wiegand products
ElectroLynx cable with Molex connector for NAC function EcoFlex electrified mortise locks
As part of their promise to provide innovative, fast and effective, and higher security solutions to their customers,
ASSA ABLOY Group companies offer ElectroLynx, a universal quick-connect system that simplifies the electrification
of the door opening. ElectroLynx™ is a trademark of ASSA ABLOY, Inc.
Designed for compatibility with ASSA ABLOY Integrated
Wiegand products and NAC Function EcoFlex mortise locks, the
ASSA ABLOY WT2 Wiegand Test Unit is a user-friendly tool that
demonstrates products features and capabilities.
The WT2 also enables field trouble shooting by verifying proper wiring,
card reader data integrity, lock functionality including: lock/unlock, door
position status, deadbolt status and REX (request-to-exit) status.
If end-of-line resistors are integrated into the product or wired into the
system, the WT2 will display these values.
If the WT2 detects line resistance above 100-Ohm on the REX or door
position sensing inputs, the unit will also display these resistance values.
Connect the WT2 directly to the lock or hinge using the provided
ElectroLynx cable.
Fail Safe /Fail Secure Selector
Open Override
Learn Button
12VDC / 24VDC Selector
To Lock
To Power Adapter
End View
Adapter
LEDs refer to the following product features:
Copyright © 2015, ASSA ABLOY Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Inc. is prohibited.
WTMN3A – PAGE 1
Door position monitoring
Request to exit monitoring
Tamper
Indicates unit powered
DX Deadbolt monitoring
7
IMPORTANT 1. Disconnect the product to be tested from access
control system before servicing.
2. Installer must be a trained, experienced
service person.
3.
Wiring must comply with applicable local electrical
codes, ordinances and regulations.
4. Unit is grounded to Common (-) for Electrostatic
Discharge (ESD) protection. Use appropriate ESD
practices when handling the unit, (i.e. standard
grounding precautions). Common (-) must be
grounded to earth (EG) at the power supply.
5. Ensure that no wires are pinched or
damaged during installation.
INSTALLATION
INSTRUCTIONS
Install product on door according to manufacturer’s instructions, which can be found at
www.intelligentopenings.com or the following:
Corbin Russwin: w w w.corbinrusswin.com
HES: www.hesinnovations.com
SARGENT: w ww.sargentlock.com
Securitron: w w w.securitron.com Yale: w w w.yalecommercial.com