Installation manual

82
Aeromax Plus Pre Commissioning Report and Checklist
Commissioning
Site Address
Installing Contractor
Size/Model of Heat Pump
Circulating pump size
Commissioning Date
Make/Model of Cylinder
Serial Number
Heat Pump Installation
Outdoor unit location correct (see manual)* Yes No
Base plate knockouts removed (see manual)* Yes No
Provision made for condensate removal* Yes No
Anti-vibration pads fitted* Yes No
Unit correctly secured to base* Yes No
Comfort Module installed* Yes No
Back-up heater installed (Bi-valent parallel system)* Yes No
Boiler installed (Bi-valent alternative system)* Yes No
Plumbing Installation
Flexible hoses installed* Yes No
Flow and return connected correctly (R top and F Bottom)* Yes No
Isolation valves installed externally* Yes No
External Pipework Insulated.* Yes No
Flush and fill ports installed* Yes No
Danfoss W Plan valve installed (Port A to Hot Water)* Yes No
Circulating pump installed on return* Yes No
System filter installed on return* Yes No
Flow setter fitted on return.* Yes No
Auto Air vent fitted at highest point.* Yes No
Is the system fitted a bivalent one* Yes No
Heat emitter type * Underfloor Radiators Fan coils Ufloor + radiators
Electrical Installation
Electrical isolation switch fitted adjacent to heat pump* Yes No
Electrical isolation switch rating* Amp
MCB/Fuse rating Amp
Link wire installed between terminals 3 & 7 on outdoor unit*† Yes No
Danfoss FP715 Hot Water programmer fitted* Yes No
Cylinder Thermostat fitted* Yes No
Danfoss TP5000 room stat fitted* Yes No
Kingspan diagnostic indicator fitted*† Yes No
Kingspan Advanced Controller (NUI) fitted (Optional).*† Yes No
Commissioning
System flushed with cleanser* Yes No
System checked for leaks* Yes No
Antifreeze added to system… concentration level. * Yes No
Air removed from primary circuit* Yes No
Pump operating* Yes No
Diverter valve operating* Yes No
Aeromax Plus operating* Yes No
Selected heat curve (enter 1 – 12 or custom)(default = 9)†
What is the flow rate set to LPM
Record Flow Temperature ° C
Record Return Temperature ° C
Record outdoor air temperature ° C
What is the bivalent point (OAT that boiler is turned on at) ° C
*Delete as required Not applicable if Comfort Module installed - see Comfort Module commissioning sheet