Installation manual
8
Minimum installation clearances in mm are shown in fig. 2 (single installation) and fig. 3 (serial installation)
Note: The height of the obstacle at both front and rear side should be lower than the height of the outdoor unit.
A B C D E F G H L weight
KHP0041
908 821 326 350 87 356 466 40 60 56
KHP0038
908 821 326 350 87 356 466 40 60 58
KHP0039
908 821 326 350 87 356 466 40 60 68
KHP0040
908 1363 326 350 174 640 750 44 69 99
KHP0042
908 1363 326 350 174 640 750 44 69 124
Safety procedures
!
CAUTION
• Ensure adequate personal protective equipment is used.
• Extraordinary maintenance operations must be carried
out by specially trained personnel.
Disconnect the mains power supply prior to any
maintenance operations or prior to handling any
internal parts of the unit.
CAUTION
• This equipment contains refrigerant that must be
disposed of in a proper manner.
• When disposing of the unit after its operational life,
remove it carefully.
• The unit must then be delivered to an appropriate
disposal centre or to the original equipment dealer
for proper environmentally compatible disposal.
!
!
Dimensions and Clearances
Specifications KHP0041 KHP0038 KHP0039 KHP0040 KHP0042
4kW 6kW 8kW 12kW 15kW
Data at Condition 1: A 7db/6wb W30/35 (EN14511)
Nominal heating capacity kW 4.1 5.8 7.2 11.9 14.5
Power input kW 1.01 1.37 1.82 3.01 3.57
Current Input (A) 4.35 5.95 7.91 13.1 15.5
COP (kW/kW) 4.05 4.24 3.95 3.94 4.06
Eurovent class, heating A A B B A
Data at Condition 2: A 7db/6wb W40/45 (EN14511)
Nominal heating capacity (kW) 3.9 5.8 7.4 12.9 14
Power input (kW) 1.22 1.90 2.32 4.26 4.36
Current Input (A) 5.3 8.26 10.1 18.5 18.9
COP (kW/kW) 3.2 3.06 3.18 3.03 3.21
Eurovent class, heating A B B B A
Water pressure drop, kPa (Condition 1) 16 9.5 14.5 26 33
Fan Power Input (kW) (Condition 1) 0.09 0.09 0.099 0.191 0.19
Fan Speed (RPM) (Condition 1) 680 680 680 710 - 730 780-820
Current Input (A) (Condition 1) 0.65 0.65 0.85 1.63 1.18
Sound power level, heating‡ dB(A) 62 62 64 67 68
Sound pressure level, heating‡ dB(A) 42 42 44 47 48
Nominal Flow Rate (l/min) 12 16.8 19.8 34.8 41.4
Nominal Flow Rate (l/min) (Radiators) 8.0 9.8 10.8 21.0 31.7
Minimum Flow Rate (l/min) (to operate flow switch) 5 8 8 8 8
Maximum Flow Rate (l/min) 15 20 25 40 50
Refrigerant Content (g) R410A 1195 1350 1810 2450 3385
Oil Type Ester Oil VG68
Compressor Type Rotary DC Inverter Technology
Net Water Volume (L) 0.8 0.8 1 2.3 2.3
Water Connections 1" ISO228 (BSP) Male
Maximum Water Pressure (kPa) 300
Product Category (EN14511) – Packaged Monobloc.
Above data applies to new, clean heat exchangers
Factory defult settings for heating are 55°C flow temp. To alter this you will be required to purchase the advanced
controller KHP0008