TP5000 Si incorporates a number of advanced features
which can be set by the user. These are accessed via a
User Advanced Programming Mode, please refer to User
Advanced Programming in the user instructions for
details (see page 67).
Installer advanced programming options
Entering Installer Advanced Programming Mode
TP5000 Si incorporates an additional number of
advanced features which can be set by the installer to
improve the operating efficiency of the system and
where required, to change the user functionality of the
product. These are accessed via an Installer Advanced
Programming Mode.
Installer advanced programming options
To access the Installer Advanced
Programming Mode follow the steps below:
a) Press and hold ˆ and PROG for 3
seconds to enter User Advanced
Programming, the display will change
to figure opposite.
b) Press and hold ‡ , ˆ and PROG for
5 seconds to enter Installer Advanced
Programming, the display will change
to figure opposite.
c) Use + and - keys to scroll backwards and forwards
between options then ‡ and ˆ keys to change the
option settings. The flashing digit on the right hand of
the display indicates the number of the selected option.
The large characters display the option value selected.
d) To return to RUN, press
c) Use + and - keys to scroll backwards and forwards between
Option 30 - Set upper limit of temperature range
This allows the upper limit of the
thermostat setting range to be elec-
tronically limited. Press + until Option
30 is displayed, use ‡ & ˆ to select
required setting.
Setting 40 - 5°C (Factory setting is 30°C)
Option 31 - Set lower limit of temperature range
This allows the lower limit of the
thermostat setting range to be elec-
tronically limited. Press + until Option
31 is displayed, use ‡ & ˆ to select
required setting.
Setting 5 - 40°C (Factory setting is 5°C)
Option 32 - Enable Off at lower limit
This enables an OFF function to be
selected if a set point below the lower
limit is selected. Press + until Option
32 is displayed, use ‡ & ˆ to select
required setting.
Setting 0 Disabled
Setting 1 Enabled (factory setting)
Option 33 - Enable On at upper limit
This enables an ON function to be
selected if a set point above the upper
limit is selected. Press + until
Option 33 is displayed, use ‡ & ˆ to
select required setting.
Setting 0 Disabled (factory setting)
Setting 1 Enabled
Programable room stat
These settings are optional and need only be made if there
is a demand for the enhanced functions.