The TP5000A Si, TP5000A-RF Si and TP5000MA Si
incorporate an input which can be used to connect one of
the following:
1) remote room temperature sensor (sold as accessory).
2) limit sensor, for example, floor temperature sensor (sold
as accessory).
3) window contacts, card reader contacts or teleswitch
contacts.
See Installer Advanced Programming Options for set-up
instructions.
Terminal block for remote control/ sensing is located on
the circuit board above the battery compartment.
Note:
Battery powered versions use S1 and S2.
Mains powered versions use D and E.
Models with remote sensor inputs
IMPORTANT
To ensure that the factory programmes are set and the microcomputer is operating correctly it is essential that you
press and hold the RESET button before you begin any commissioning or programming.
Please Note:
Some existing thermostats will have a Neutral and/or Earth wire connected. These are not required by the battery
powered versions of the TP5000 Si and must NOT be connected to any battery powered TP5000 Si terminals.
Instead they should be made electrically safe and coiled in the recess at the back of the TP5000 Si.
/D
/E
Remote
control
connections
Battery powered
versions
RX1
RX2 & RX3
S1/D
S2/E
Window or
teleswitch
contact (NO
or NC)
S1/D
S2/E
Teleswitch
contact (NC)
Window
contact (NC)
Configured for
remote room
sensor or
limit
Configured for
window contact or
other contact such
as teleswitch
Configured for
window contact
and other contact
such as teleswitch
RX Receiver Wiring (RF models only)
1) For mains voltage operated systems link terminal 2 to
mains live supply.
2) Power supply to unit must not be switched by
timeswitch.
Commissioning (RF models only)
If the thermostat and the receiver have been supplied
together in a combined pack, the units have been paired
in the factory and no commissioning is required (RX1
only). To make the RX receiver learn the thermostats
signal, follow steps 1-5.
Step 4
RX2 (if applicable)
Stat 1 - perform steps 1-3 and 5.
Stat 2 -perform steps 1-2 and then press PROG and CH2
on RX2.
RX3 (if applicable)
Stat 1 - perform steps 1-3 and 5.
Stat 2 - perform steps 1-2 and then press PROG and CH2
on RX3 then step 5.
Stat 3 - perform steps 1-2 and then press PROG and CH3
on RX3.
Step 5: TP5000Si-RF - Press or ˆ to select
temperature - the unit will revert back to operating mode.
RX1 - Press and hold buttons PROG a n d CH 1 for
Programmable room stat
Step 1:TP5000-RF Si - Reset the unit
by pressing the recessed reset button.
Step 2: Press and hold ˆ and +
buttons for 3 seconds (TP5000 RF Si
now transmits unique signal
continuously for 3 minutes).
Step 3: RX1 - Press and hold buttons
PROG and CH1 for 3 seconds until
green light flashes once.