Installation manual
56
Programmable room stat
• First, remove the wallplate from the back of the unit.
• From the top left hand corner of the wallplate, there
must be clearances of at least 15mm to the right,
15mm to the left, 30mm above and 100mm below in
order to mount the plug-in module.
• Thermostat and Remote Room Sensor: Fix at a height
of approximately 1.5m from the floor, away from
draughts or heat sources such as radiators, open fires
or direct sunlight.
• Prior to mounting the unit the 2 DIL switches on the
rear of the unit have to be moved to the required
position. The factory presets are shown opposite
Installation
When installing the batteries in the TP5000 Si and
TP5000 Si RF please ensure that the correct polarity
is observed as per the markings on the inside of the
battery compartment.
Battery Installation
IMPORTANT: After installing the batteries press and
release the RESET button to start the unit. The display
may appear blank until this is done. Once the button is
released the display will appear. All date, time,
programming and override settings are maintained for the
life of the product.
Cable Access
1
2
3
N
L D E
A B
C
D E
24V
Output Connections,
all hard wired models
Power Supply Connections
M 230V Models
M 24V
Remote
Sensor
Remote
Sensor
0V
Wiring