Installation manual

43
Installation & User Instructions
Installation
Product specification 43
Installation 44
Wiring
DIL switch settings
Advanced Programming Options 45
Copy Functions
Service Interval Timer 46
User
What is a programmer? 46
Your timeswitch 47
Preset programmes
Before you start
AM/PM or 24hr display
Setting the Time and Day 48
Accepting the preset programmes
Changing the preset programmes
Programming system - 5/2 day 49
Programming system - 7 day 50
Programming system - 24 hour 51
Running the programme
Temporary overrides 52
Holiday Programme
Changing clocks forward/back 53
Service Interval Timer
Making a full reset 54
Troubleshooting
Index
DAY/HO
L
+1HR override
MAN override
RESET
Mode
SELECT
+1HR
MAN
Please Note:
This product should only be installed by a qualified electrician or competent heating installer, and should be
in accordance with the current edition of the IEEE wiring regulations.
Product specification
Specification 230V Model 24V Model
Power supply 230 Vac, ±15%, 50/60 Hz 24Vac, ±15%, 50/60Hz
Switching action 1 x SPDT voltage free, Type 1B
Switch rating 24 - 230 Vac, 3(1)A
Battery back-up 24 hours minimum
Setting/Running Accuracy ±1 minute
Dimensions, mm (W, H, D) 135 x 88 x 32
Design standard EN 60730-2-7
Control Pollution Situation Degree 2
Rated Impulse Voltage 2.5kV
Ball Pressure Test 75°C
7 day hot water programmer