Information
58 APEMwww.apem.com
“I” range
Sealed pushbutton switches
Sealing
SEALING IP67
IP 6 7
(Ingress Protection) Totally protected Protected against the effects of
against dust immersion up to 1 m water (30 mn)
The illustrations show non-
illuminated models.
ADDITIONAL SEALING FOR IP-IB-IS SERIES
For ROUND plungers only, illuminated or non-illuminated.
By silicone boot for protection against frost and abrasion by sand. Order separately.
- transparent : U5125
- blue : U5125-1
- black : U5125-2
- red : U5125-6
Operating temperature : -40°C to +85°C
Life expectancy : 500.000 cycles
Note : the flat seal should not be used in this case.
(.748 DIA)
Ø19.00
(.377)
9.60
ADDITIONAL SEALING FOR IA SERIES
By silicone boot. Order separately.
- Black : U6602
- Yellow : U6605
- Red : U6606
Operating temperature : -40°C to +85°C
Life expectancy : 1.000.000 cycles
(.826 DIA)
Ø21.00
(.267)
6.80
Ø16.00
(.629 DIA)
SEALING IP69K
➀ Elastomeric membrane
Degree of protection provided by the enclosures of electric appliances according to IEC 60529, DIN 40050 and NFC 20-010.
IP69K test conditions
. Pressure : 80 - 120 bars
. Distance : 15 cm
. Temperature : 80°C ± 5°C
.
Flow : 14 - 16 l/mn
. Duration : 30 seconds per position
High pressure, high temperature wash down
1