Datasheet

• Max. current/voltage ratings : see tables below
• Peak current : 30 A max. during 1/2 sine, 250 VAC
• Initial contact resistance : 10 mΩ max.
• Insulation resistance : 1,000 MΩ min. at 500 VDC
• Dielectric strength :
2,000 Vrms 50 Hz min. between terminals
2,500 Vrms 50 Hz min. between terminals and frame
• Electrical life : 10,000 cycles at full load
ELECTRICAL SPECIFICATIONS
APPROVED RATINGS
Models Functions
600H - 600NH
UL CSA NF-VDE
UL 1054 CSA 22-2 EN 61058-1
Single and
double pole
ON - OFF (1)
15 A 1/2 HP
125-250 VAC
10(4) A
400 VAC
T 85/55 (600H)
T 125/55
(600NH)
ON - ON (6)
Other
(4-5-7-8-9)
10 A 1/2 HP
125-250 VAC
Three pole
ON - OFF (1)
& ON - ON (6)
15 A 1/2 HP
125-250 VAC
Other
(4-5-7-8-9)
10 A 1/2 HP
125-250 VAC
FOR INFORMATION
Max. current/voltage rating w. resistive load
Functions Ratings Electrical life
ON - OFF
ON - ON
15 A 250 VAC
10 A 24 VDC
15 A 12 VDC
10,000 cycles
ON OFF ON
15 A 250 VAC
5 A 24 VDC
6,000 cycles
10,000 cycles
Other
15 A 125 VAC
12 A 250 VAC
5 A 24 VDC
10,000 cycles
Robust mechanism
High current/voltage rating
Insulated or metal lever
UL, CSA and NF-VDE (EN 61058-1) approved
DISTINCTIVE FEATURES
600H-600NH
series
Toggle switches • high amperage
The company reserves the right to change specifications without notice.
PANEL SWITCHES
1