Owner's Manual

4
INSTALLATION DIAGRAM
Pre installation preparation:
The media in the water treatment system does not have to be pre soaked, however after the system is in-
stalled, please manually backflush the unit once before use. The timer control valve has been factory pre
programmed to regenerate once a week, but you can set the regeneration time to your preference. You
basically will just need to set up the time of day. Please refer to pages 5-6 to manually backflush the unit
and general setup.
Please note: The Control valve of the system only requires
3 connections. Inlet, Outlet and Drain Line.
DO NOT connect the Brine Line. The Brine line is only used
when salt is needed like in a water softener application.
Drain
line
Out
In
Do Not
Connect
Brine
line
*
Figure. 5
Determine installation location for the system:
A electrical outlet will be required for the system.
Do Not install the units with less than 5-10 feet of piping between its outlet and the inlet of the water
heater.
Do Not install the units where the location is subjected to room temperatures under 34 degrees Fahr-
enheit.
The tanks should be on a firm, level surface.
Provided the drain line is not reduced, the drain line for the system should not exceed 5 feet Vertical.
It is best to use a 1/2” ID (inner diameter) or larger drain line.