Owner`s manual
4
THERE ARE THREE PARTS TO INSTALLING THE RO SYSTEM:
Part I. Assemble the filters and housings onto the main system
Part II. Placing the Membrane into the membrane housing
Part III. Installing the system
PART I. ASSEMBLE THE FILTERS AND HOUSINGS ONTO THE MAIN SYSTEM
Remove plastic/paper wrappings on the 3 filters, put them into the 3 housings, and assemble the
housings onto the main system as follow:
Fig. 1 Stand the 3 housings upright. Make sure each housing has a rubber O-ring in its
groove.
Put the “Puretrex 5 micron” sediment filter into the “1
st
stage” housing on the right.
Put the “Matrikx +CTO” carbon filter into the “2
nd
stage” housing in the middle.
Put the “Matrikx +CTO” carbon filter into the “3
rd
stage” housing on the left.
Fig. 2 Starting from the 3
rd
stage housing on the left, hand twist the housing onto the main
system turning counterclockwise, one by one, for all 3 housings.
Fig. 3 Use the wrench provided to completely tighten the housing starting from 1st-stage.
Repeat this step for the 2
nd
stage housing in the middle, and for the 3
rd
stage hous-
ing on right.
Note: For some people it is easier to use the wrench with the system laid down
(face up).
Fig. 1 Fig. 2 Fig. 3
3rd
Stage
2nd
Stage
1st
Stage
Use
Wrench