How to connect: - See Fig. 10A. Slide the compression nut onto the tubing.
- Insert the
“insert into the tubing.
- Insert the tubing into the opening of the fitting.
- Slide the nut up, then tighten nut with a wrench. No Teflon tape!
3. Quick-Connect fitting (no insert, sleeve, or nut)
Fig. 10B Fig. 10C
How to Connect: - See Fig. 10B. Simply push the tubing into the Quick-Connect fitting.
- No inserts, sleeve, or nuts are needed to secure the connection.
- No Teflon tape!
To Disconnect: - See Fig. 10C. Push in and hold down on the collet ring around the
base of the fitting, then pull out tubing.
Summary of Tubing Connections:
There are 4 connectionsions: See Fig 11 and 11A
Point A to X: Connect RO to COLD water supply — Red tubing.
Point G to Y: Connect product water from 5
th
-stage filter to tank — Yellow tubing. This tubing
is a 2-way line, Product water enters and leaves the tank via this line.
Point H to Z: Connect product water from 5
th
-stage output to RO faucet — Clear tubing.
Drain line to W: Connect waste water from 4
th
-stage membrane to drain outlet — Black tubing.