Use and Care Manual

5
The Stage-1 Sediment filter is tucked behind the membrane housing. For ease of access, pull and lift the
2nd stage filter to the top position. Then, do the following:
Step 1.
Step 2.
Disconnect tubing from Point D & Point E (see Figure D) Discard used filter.
(Follow “Quick-Connection Guide” for connection tips)
Snap on the new filter onto the 2 holding clips. Make sure the Flow direction “arrow ”
on the filter is pointing toward the right direction (see Figure D). Re-connect tubing to both
ends of the new filter.
How to Replace Stage-1 Sediment Filter (CT-1SED)
Change every 6 months or 600-800 gal pure water used:
Figure D
(Back View Of System)