Use and Care Manual

16
How to Replace Stage-4 Membrane:
There are several membranes (2 to 4 depending on model) provided with your system. Please
insert the membrane into each housing one-by-one to prevent mis-connecting the tubing.
1. Locate the Membrane housings on the system. See Fig 8
2. The number of housing matches with the number of membranes provided. Each housing is
labeled as: “MEM-1”, “MEM-2”, “MEM-3”, “MEM-4” depending on your Ro model.
3. Start with “MEM-1” housing: Insert the membrane into one housing at a time. Finish up the
connection before going onto the next housing. This will prevent confusing the tubing order.
Insert membrane: See Fig.8A Remove the tubing from the membrane housing cap. Open the
cap. Insert membrane all the way into the housing tightly with the correct side going in first as
shown below. The end with 2 black-rings goes in first.
4. Close the housing cap. Re-connect the tubing to cap as before. Make sure to connect each
color coded tubing to its corresponding (matching) housing. This is important for proper filtra-
tion.
5. Proceed to insert the other membranes in the same manner.
Note: Make sure the membrane’s end with 2 black-rings goes into housing first!
Fig. 8A
1. Push in and hold down on the collet ring
square against the tting. With the collet
held in this position the tube can be removed.
2. Unscrew membrane housing
cap (counter clockwise)
b
an
e
ho
us
in
Post Carbon Filter
Fig. 8