User manual

- 85 -
fail
ERROR
SATA revision id
fail
Failed to get SATA revision id
ERROR
SATA set reg fail Failed to set SATA register
ERROR
SATA init fail Core failed to initialize the SATA adapter
ERROR
SATA diag fail SATA Adapter diagnostics failed
ERROR
Mode ID fail SATA Mode ID failed
ERROR
SATA chip count
error
SATA Chip count error
INFO
SAS port reply
error
SAS HBA port <number> reply terminated abnormally
INFO
SAS unknown port
reply error
SAS frontend reply terminated abnormally
INFO
FC port reply error FC HBA port <number> reply terminated abnormally
INFO
FC unknown port
reply error
FC frontend reply terminated abnormally
EMS events
Level Type Description
INFO
Power install Power(<string>) is installed
ERROR
Power absent Power(<string>) is absent
INFO
Power restore Power(<string>) is restored to work.
ERROR
Power fail Power(<string>) is not functioning
WARNING
Power detect PSU signal detection(<string>)
INFO
Fan restore Fan(<string>) is restored to work.
ERROR
Fan fail Fan(<string>) is not functioning
INFO
Fan install Fan(<string>) is installed
ERROR
Fan not present Fan(<string>) is not present
ERROR
Fan over speed Fan(<string>) is over speed
WARNING
Thermal level 1 System temperature(<string>) is higher.
ERROR
Thermal level 2 System Overheated(<string>)!!!
ERROR
Thermal level 2
shutdown
System Overheated(<string>)!!! The system will auto-
shutdown immediately.
ERROR
Thermal level 2
CTR shutdown
The controller will auto shutdown immediately, reason
[ Overheated(<string>) ].
WARNING
Thermal ignore
value
Unable to update thermal value on <string>
WARNING
Voltage level 1 System voltage(<string>) is higher/lower.
ERROR
Voltage level 2 System voltages(<string>) failed!!!
ERROR
Voltage level 2
shutdown
System voltages(<string>) failed!!! The system will
auto-shutdown immediately.
ERROR
Voltage level 2
CTR shutdown
The controller will auto shutdown immediately, reason
[ Voltage abnormal(<string>) ].
INFO
UPS OK Successfully detect UPS
WARNING
UPS fail Failed to detect UPS
ERROR
UPS AC loss AC loss for system is detected
ERROR
UPS power low UPS Power Low!!! The system will auto-shutdown
immediately.
WARNING
SMART T.E.C. Disk <slot> S.M.A.R.T. Threshold Exceed Condition
occurred for attribute <string>
WARNING
SMART fail Disk <slot>: Failure to get S.M.A.R.T information
WARNING
RedBoot failover RedBoot failover event occurred
WARNING
Watchdog
shutdown
Watchdog timeout shutdown occurred
WARNING
Watchdog reset Watchdog timeout reset occurred