User guide
Technical Specifications
96-00290-001 Rev. A1 DataDirect Networks StorageScaler 2460 User Guide | 29
Here are the technical specifications for StorageScaler 2460.
NOTE :
Specifications subject to change without notice.
A.1 General Specifications
System
• 2U enclosure height (rack configurations)
• Up to 24 2.5" SAS or SATA disk drives (including SSD’s) per enclosure (6 Gb/sec or
3 Gb/sec)
Redundant Components
• Two APC units
• Up to 24 drives per enclosure
Field Replaceable Units
• Disk drives and drive carrier blanks
•APC units
• I/O modules
• I/O module slot blanks
Enclosure Physical Dimensions
• Height: 3.5" (89 mm)
• Width: 17.6" (447 mm)
• Depth: 19.3" (49 mm)
• Weight: up to 53 lbs (27 kg) maximum (with all drives installed)
Advanced Power and Cooling (APC) Units
• Input Voltage: 100–240 VAC
• Current Rating: 8.40 A (max)
• Input Frequency: 50/60 Hz
• Outputs:
- +5 V @ 28 A
- +12 V @ 43 A
• Maximum Average Output Power: 550 Watts
• Cooling: Variable speed blowers, two per APC for a total of four blowers per enclosure
NOTE :
APC units are hot-swappable.