User guide
Monitoring Your SS2460
96-00290-001 Rev. A1 DataDirect Networks StorageScaler 2460 User Guide | 21
3.3 Monitoring the Disk Drives
Each disk drive carrier has three LEDs that indicate the status of the disk drive (Figure 27).
The LEDs are defined in Table 3.
NOTE :
If replacing a disk drive does not resolve a fault or failure indicated by the
Fault LED, replace the I/O controller (see Section4.2).
Table 3. Disk Drive Carrier LED Description
LED Color Description
Locate Beacon Blue Flashes - receiving Locate command
OFF - NOT receiving Locate command
Fault Amber ON - a detectable fault is present
OFF - no detectable fault is present
Status Green ON - power is applied to disk
Flashing - indicates disk activities
Figure 27. Disk Drive Carrier LEDs
Fault
Status
Locate