Monitoring Your SS2460
96-00290-001 Rev. A1 DataDirect Networks StorageScaler 2460 User Guide | 20
3.2 Monitoring the Controllers
Each controller has 11 status LEDs (Figure 26). The LEDs are defined in Table 2.
Figure 26. Controller Status LEDs
OK/Power
Ethernet LEDs
SAS Link Fault
SAS Link
Established
Locate
I/O Fault
When a fault condition occurs on a controller, the enclosure LEDs indicate an enclosure
fault. Because the controllers are on the back of the enclosure where they may be hard to
see, always check controller status whenever the enclosure LEDs indicate a fault.
When the controller Fault LED illuminates, replace the controller (see Section 4.2).
Table 2. I/O Controller LED Description
OK / Power Green
I/O Module Fault Amber
Locate Beacon Blue
SAS Link
Established
Green
SAS Link Fault Amber
Ethernet Link Green
Ethernet Activity Amber
LED Color Description
ON - the I/O module is properly booted and is func
tioning properly
OFF - the I/O module has detected an internal fault
ON - an I/O module fault has been detected
OFF - no detec
table I/O module faults
Flashes - receiving Locate command
OFF - NOT r
eceiving Locate command
ON - a valid SAS link is established on at least one of the four SAS links
of the 4-wide SAS port
OFF -
no valid SAS link is established on any of the four SAS links of the
4-wide SAS port
ON - a detectable fault is present on at least one of the four SAS links of
the 4-wide SAS por
t
OFF - no detectable fault is present on any of the four SAS links of the
4-wide SAS ports
ON - Ethernet link is up
OFF -
Ethern
et link is down
Flashes - Ethernet link is active; the fr
equency tha
t it will blink is 10 Hz