System information

Appendix
D-50
Security control
Event ID
0x2416
Type
SYSTEM
Severity
INFO
Parameters
DISK ID
Message
NVRAM configurations restored from HDDx
Description
The NVRAM configurations were restored from hddx.
Advice
None
Event ID
0x2417
Type
SYSTEM
Severity
INFO
Parameters
Message
NVRAM configurations restored from file
Description
The configurations were restored from a file uploaded to the controller.
Advice
None
Event ID
0x2409
Type
SYSTEM
Severity
FATAL
Parameters
Message
NVRAM configuration checksum error
Description
The checksum stored on NVRAM do not match the contents on NVRAM. This could happen if the
controller was not properly shutdown. Because NVRAM configurations might be corrupt and can-
not be trusted, all event logs are automatically erased.
Advice
Restore the configurations from hard disks or by uploading the backed-up configuration file. If this
event happens continuously, contact local sales or support office.
Event ID
0x2431
Type
SYSTEM
Severity
FATAL
Parameters
Controller ID
Message
NVRAM mapping table on controller x checksum error
Description
The checksum stored on NVRAM cannot match the contents on the NVRAM. This could happen
during the controller is not properly shutdown. System will restore default the default mapping
table automatically
Advice
Start to monitor more carefully the status of the NVRAM.
Event ID
0x240d
Type
SYSTEM
Severity
INFO
Parameters
Message
Admin login
Description
Administrator login to the controller.
Advice
None