System information

Appendix
D-41
Event ID
0x242b
Type
CONTROLLER
Severity
ERROR
Parameters
Controller ID
Message
Bootrom in controller x is corrupt
Description
Bootrom on controller x is corrupt and cannot be used. Because the bootcode is stored on the
bootrom, the controller cannot work.
Advice
Check if the power supply is stable. Replace with a new controller. Contact local sales or support
office.
Event ID
0x2423
Type
CONTROLLER
Severity
INFO
Parameters
Bad block num-
ber, Controller ID
Message
Bad block x on primary system flash added in controller y
Description
Bad blocks happened and remapped successfully on the primary system flash in controller y.
Advice
Check if there are any hardware hazards that lead to abnormal flash corruption. Watch the sec-
ondary flash chip.
Event ID
0x2424
Type
CONTROLLER
Severity
INFO
Parameters
Bad block num-
ber, Controller ID
Message
Bad block x on secondary system flash added in controller y
Description
Bad blocks happened and remapped successfully on the secondary system flash in controller y.
Advice
Check if there are any hardware hazards that lead to bad blocks. Watch the secondary flash chip.
Event ID
0x2425
Type
CONTROLLER
Severity
WARNING
Parameters
Controller ID
Message
Bad block on primary system flash over 70% in controller y
Description
The amount of bad blocks is over 70% of the table that is used to remap bad blocks.
Advice
Check if there are any hardware hazards that lead to bad blocks. This flash chip is close to fail.
Event ID
0x2426
Type
CONTROLLER
Severity
WARNING
Parameters
Controller ID
Message
Bad block on secondary system flash over 70% in controller y
Description
The amount of bad blocks is over 70% of the table that is used to remap bad blocks.
Advice
Check if there are any hardware hazards that lead to bad blocks. This flash chip is close to fail.