System information
Appendix
D-24
• Disk port and chip
Event ID
0x081b
Type
DISK
Severity
ERROR
Parameters
Disk port ID, Con-
troller ID
Message
Reset disk port x in controller y
Description
The controller y resets disk port x that failed to execute commands properly. This could be a tran-
sient error due to unstable channel, heavy traffic, or malfunctioning hard disks. The controller will
resume normal operations after reset; however, this could result in performance drop of the disks
attached to the disk port.
Advice
If this event occurs often, check the disk connectivity, check power supply to disks, or replace with
a new disk.
Event ID
0x081c
Type
DISK
Severity
WARNING
Parameters
Chip ID, Control-
ler ID
Message
Reset disk i/f chip x in controller y
Description
The controller y resets chip x that failed to execute commands properly. This could be a transient
error due to unstable channel, heavy traffic, or malfunctioning hard disks. The controller will
resume normal operations of the chip after reset; however, this could result in performance drop of
the disks attached to the disk ports of this chip.
Advice
If this event occurs often, check the disk connectivity, check power supply to disks, or replace with
a new disk.
Event ID
0x081d
Type
DISK
Severity
FATAL
Parameters
Chip ID, Control-
ler ID
Message
Disk i/f chip x in controller y failed
Description
The controller y cannot execute commands properly on chip x after all appropriate recovery proce-
dures were conducted. This could be the result of unstable power supply to the system. All disks
controlled by the chip will fail.
Advice
Check power supply, replace with a new controller, or contact local sales or support office.
Event ID
0x081f
Type
DISK
Severity
ERROR
Parameters
Disk Channel ID,
Controller ID, Reg-
ister value
Message
Disk channel x in controller y PCI Error cause register: z
Description
The controller y has detected error in the disk channel.
Advice
Check if the power supply is stable. Contact local sales or support office.