System information

Appendix
D-4
Spare
Event ID
0x2051
Type
RAID
Severity
WARNING
Parameters
DG ID, LD ID
Message
Logical disk init on DGxLDy aborted
Description
Logical disk initialization task on dgxldy was aborted.
Advice
Check if any disks in the disk group failed, and then re-create the logical disk.
Event ID
0x2064
Type
RAID
Severity
NOTICE
Parameters
Zeroing progress,
DG ID, Notify
threshold
Message
Write zero progress(y%) on DGx reach to the notify percent(z%)
Description
The progress of zeroing DG has reached the notify threshold.
Advice
None
Event ID
0x2066
Type
RAID
Severity
NOTICE
Parameters
Init progress, DG
ID, LD ID, Notify
threshold
Message
Logical disk init progress(w%) on DGxLDy reach the notify percent(z%)
Description
The progress of initializing logical disk has reached the pre-define threshold.
Advice
None
Event ID
0x0804
Type
RAID
Severity
INFO
Parameters
Disk ID
Message
Global spare HDDx added
Description
hddx was selected to be a global spare.
Advice
None
Event ID
0x0805
Type
RAID
Severity
INFO
Parameters
Disk ID
Message
Global spare HDDx removed
Description
Global spare hddx was changed to be an unused disk.
Advice
None
Event ID
0x1002
Type
RAID
Severity
INFO
Parameters
Disk ID, DG ID
Message
Local spare HDDx of DGy added
Description
hddx was selected as local spare of dgy.
Advice
None