Specifications
Falcon 24 Bay SCSI-SATA Installation and Hardware Reference Manual
NOTE:
To create dual redundant data paths on the host side, it is necessary to install high
availability software on the application servers.
4.3 Power On
Once all the components have been installed in the Falcon subsystem, the host channels
have been connected to the host, and the expansion cables have been connected to
another subsystems or JBODs, the subsystem can be powered on.
4.3.1 Check List
BEFORE powering on the Falcon subsystem, please check the following:
… Memory modules – Memory modules have been correctly installed on the
controller boards.
… BBU modules – If used, that the BBU modules have been installed correctly.
… Hard drives Hard drives have been correctly installed on the drive trays.
… Drive trays – ALL the drive trays, whether or not they have a hard drive, have
been installed into the subsystem.
… Cable Connections The host ports and management access on the subsystem
have been correctly connected to a host computer.
… Power cables The power cables have been connected to the AC power sockets
on PSU modules and plugged into main power.
… Ambient temperature – All the subsystem components have been acclimated to
the surrounding temperature.
4-10
Power On