1.1.2.4 Drive Slot Numbering
The front section of the enclosure houses twenty-four (24) hard drives as shown in
Figure 1-4. When viewed from the front, the drive bays (slots) are numbered 1 to 24
from left to right, then from top to bottom.
Slot-1 Slot-2 Slot-3 Slot-4
Slot-5 Slot-6 Slot-7 Slot-8
Slot-9 Slot-10 Slot-11 Slot-12
Slot-13 Slot-14 Slot-15 Slot-16
Slot-17 Slot-18 Slot-19 Slot-20
Slot-21 Slot-22 Slot-23 Slot-24
Figure 1-4: Hard Drive Slot Numbering
1.1.2.5 Rear Panel Overview
Figure 1-5: Falcon 24 BAY RAID Subsystem Rear View
The rear panel of the 24 BAY subsystem is shown in Figure 1-5. The rear panel
provides access to all the components located in the rear half of the RAID subsystem
enclosure.
Three (3; N+1) redundant, hot-swappable 405W PSU modules connect the subsystem to
the main power source. Two (2) redundant, hot-swappable dual-fan cooling modules are
located above the PSU modules. One power switch on the chassis rear panel controls all
PSU modules. Each PSU module contains two cooling fans.
Product Overview