Product specifications
Appendix B: Specifications
B.5 Cooling Module Specifications
Specifications
Max. Air Flow High speed: 31.8 CFM
Low speed: 20.1 CFM
Input Power
9 W max.
Input Current
0.89A max.
Rated Voltage
DC 12V
High speed: 55dB max.
Acoustic Noise
Temperature
Low speed: 44dB max.
Operating: -10 to +60ºC
Storage: -20 to +70ºC
B.6 RAID Management
Specifications
Configuration
Performance
•
Text-based firmware-embedded utility over
RS-232C through the included serial cable
•
LCD keypad panel
•
The RAIDWatch Manager program using in-
band or Ethernet connection
Monitoring
Yes
Remote Control and
Monitoring
Yes
Event
Broadcast/Alert
Yes, via Java-based RAIDWatch Manager and
Event Monitor
Event Notification
Yes, via the RAIDWatch Configuration Client
sub-module
Hardware Connection
In-band over SCSI/Fiber, out-of-band via Ethernet
or RS232C
Configuration on
Disk
Failure Indicator
Configuration data stored on disks for logical drive
assemblies to exist after controller replacement.
Faults are indicated via alarm, module LED
indicators, LCD panel, RAIDWatch Manager, or
terminal emulation.
Cooling Module Specifications