Product specifications
Falcon II SCSI-SATA Installation and Hardware Reference Manual
FALCON II
256MB RAM, Wait
FALCON II
No Host LUN
4.5 Power Off Procedure
Verifying installed cache memory.
System is ready. You can now start to
configure the subsystem.
If you wish to power down the FALCON II, please follow these steps:
NOTE:
If you wish to power down the FALCON II, please ensure that no time-
consuming processes, like a logical drive parity check or a
background scrub, are running.
1. Stop I/O access to the system.
Use the software provided on the host computer to stop all IO accesses
to the FALCON II. Please refer to the user’s manual that came with
your host computer.
2. Flush the cache.
Use the “Shutdown Controller” function to flush all cached data. This
prepares the RAID subsystem to be powered down.
3. Turn off the power.
Turn off the power switches at the top of the rear panel of the
FALCON II. Once the subsystem has been powered down, other devices
that are connected to the subsystem may be powered down.
4-8