Product specifications
Falcon II SCSI-SATA Installation and Hardware Reference Manual
The thresholds in Table 3-7 are default threshold values and may be
changed. To see how to change these values, please refer to the Generic
Operation Manual on the CD that came with your system.
3.3.2 Failed Devices
If any of the following devices fail, the audible alarm will be triggered:
•
RAID controller module
•
Cooling modules
•
PSU modules
•
BBU
•
Hard drives
NOTE:
When the temperature exceeds a preset threshold, the controllers
charger circuits will stop charging. You will then receive a message that
says Thermal Shutdown/Enter Sleep Mode. When the temperature falls
back within normal range, the battery will resume charging.
3.4 I
2
C Monitoring
Presence detection and the general working status of the cooling fan and
other modules are monitored through an I
2
C serial bus. If any of these
modules fail, you will be notified via the various methods described above.
3-10
IP2PC Monitoring