User Manual

Back-UPS Pro BR650MI / BR900MI / BR1300MI / BR1600MI8
Function Button Quick Reference
Function Button
Timing
(seconds)
UPS
Status Description
Power
Power On 0.2 Off
Press POWER to start receiving input AC power. If AC
input power is not available, the Back-UPS will run on
battery power.
Power Off 2On
The Back-UPS is not receiving input AC power, but is
providing surge protection.
Display
Status
Inquiry
0.2 On
Verify the status or condition of the Back-UPS. The
LCD will illuminate for 60 seconds. Press the button
the toggle into various information.
Full-Time/
Power-
Saving
mode
2On
The LCD will illuminate and the Back-UPS will beep
to confirm the Full-Time mode. The LCD will darken
and the Back-UPS will beep to confirm the Power-
Saving mode. While in Power-Saving Mode, the LCD
will illuminate if a button is pressed, then darkens after
60 seconds of no activity.
Mute
General
Status
Enable/
Disable
2On
Enable or disable the audible alarms. The Mute icon
will illuminate and the Back-UPS will beep one time.
The Mute function will not activate unless the Back-
UPS is operating on battery power.
Sensitivity 6Off
The Load Capacity icon will blink, indicating that the
Back-UPS is in programming mode. Use the P
OWER
button to scroll through Low, Medium, and High, stop
at selected sensitivity. The Back-UPS will beep to
confirm selection. See "Unit sensitivity" for details.
Self-Test
(manual)
6On
The Back-UPS will perform a test of the internal
battery. Note: This will happen automatically when the
Back-UPS is turned ON or when the Back-UPS
previously detected a bad battery.
Event
Reset
0.2 On
When the Event screen is visible, press and hold
D
ISPLAY, then press POWER, to clear the detected error
event counter.
Error
Reset
2Error
After an error has been identified, press POWER to
remove the visual indication and return to standby
status.