User manual
G-Type Rack Power Filter: Operation10
LED dimmer. Set the brightness of the LEDs.
Delay1-Delay4. Select the number of seconds for the delay for DELAY outlets 1, 2A, 2B, 3, and 4.
Power Threshold. The amount of power used by a device in Sleep or Standby mode varies between
devices. It may be necessary to adjust the threshold at which the Master outlet signals the Controlled
outlets to shut down.
1. Ensure a master device is connected to the Master outlet. Put that device into Sleep or Standby
mode, or turn it OFF.
2. Press
STATUS and hold for three seconds.
3. The G50 will now recognize the standby power threshold of the Master device and save it as the
new threshold setting. Use the
UP or DOWN arrow key to adjust the power threshold.
Green Function. Use the Up and Down arrow buttons to enable or disable the Green Function. The
Green Function allows you to utilize the
MASTER and CONTROLLED outlets. When the device plugged into
the
MASTER outlet goes into Sleep or Standby mode, or turns off, the equipment that is connected to the
CONTROLLED outlets will also turn off, saving electricity.
Utility Rate. Enter electrical power utility rate in cents/kWh (USD only). The unit will use this to
calculate the savings accumulated when using the green function
MASTER and Controlled outlets.
Contact Information. This screen can be customized to include the contact information of the A/V
dealer or installer. Push the
STATUS button to move the cursor to the next letter and use the Up and Down
arrow buttons to scroll to the appropriate letter.
Maximum and Minimum Voltages. Set the voltage range in which the unit should normally operate.
The unit will protect connected equipment from high and low voltages that are not safe for operation.
LED DIMMER:
DIM1
DELAY 1:
4SEC (0-255)
POWER THRESHOLD:
10 W (10-85)
GREEN FUNCTIONS
DISABLE
UTILITY RATE
12 cents/kWh
1-888-882-7228
WWW.APCAV.COM
MAX UPPER VOLT:
140V (132-140)
MIN LOWER VOLT:
92V (92-100)