User Manual C Type Wall Mount Power Filter C2C
© 2009 APC by Schneider Electric. APC, the APC logo, and TRADEMARK NAMES are owned by Schneider Electric Industries S.A.S., American Power Conversion Corporation, or their affiliated companies. All other trademarks are property of their respective owners.
Safety Information 1. Read this manual - Read all of the safety and operating instructions before installing and operating this device. 2. Keep this manual - Retain this manual, and all of the safety information that came with this device. 3. Warnings - Comply with all warnings presented in this manual, as well as any found on the device. 4. Follow Instructions - Follow all operating and use instruction. 5. Cleaning - Unplug this device from the wall outlet before cleaning.
Safety Information (Continued) 14. Overloading - Do not overload the wall outlet where this device is being connected. Do not overload this device. Ensure the total load to this device does not exceed that which is listed in the Specifications section of this manual. 15. Servicing - There are no user-serviceable components within this device. Removal of any cover from this device may present a shock hazard, and/or void the warranty. 16.
Protect Your Investment Congratulations and thank you for selecting and investing in APC’s Model C2C Wall Mount Power Filter. At APC, we know you have made an intelligent choice sure to reward you for many years. To ensure you receive all the benefits and protection that accompany your purchase, please take a few minutes to fill out and mail the enclosed Warranty Registration Card, or complete the online form at: www.apc.com.
Class B Labeling and Instruction Manual Requirements Devices subject to Certification must be labeled with an FCC Identifier. Devices subject to Verification or Certification must be labeled with the following compliance statement: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Table of Contents Safety Information i Protect Your Investment iii Class B Labeling and Instruction Manual Requirements iv Introduction Proven Expertise…Proven Reliability Safety Precautions Package Checklist Unit Power Capacity 1 1 2 2 3 Features Surge Protection Isolated Noise Filter Banks Full Outlet Coverage 3 3 3 3 Side Panel Indicators 4 Outlet Panel 6 Installation Apply Power Making Connections FCC Compliance Information 7 7 7 7 Technical Specifications 8 Troubleshooting 9 APC Tec
vi
Introduction Congratulations on purchasing APC’s C2C Wall Mount Power Filter, shown in Figure 1. The C2C is designed for the unique mounting requirements of flat panel displays such as plasma displays, LCDs and projectors, and will protect your high performance audio and video (AV) equipment from damage caused by power surges, spikes and lightning. Protection is guaranteed.
world. Over the last 20 years, APC has been a pioneer in the development of new power protection technologies that have resulted in countless industry awards, patents, and an installedbase numbering in the tens of millions of units. Multiple R&D centers, along with APC-owned and controlled factories ensure APC solutions are the safest, most advanced and reliable products available. When you buy APC, you buy “peace of mind.
Unit Power Capacity The C2C is rated for 12 Amps. The C2C is capable of supplying the dynamic peak current draws required by any component designed to work on a 15 A circuit. Despite their nameplate power ratings, high performance AV equipment draws much less than their listed power ratings. The C2C can inform the user of how much power is still available as each device is connected to the C2C unit. Features The following paragraphs describe the major features of the Model C2C Power Filter.
Side Panel Indicators The following section describes the LED indicators on the C2C’s side panel. The side panel controls and indicators for the C2C Power Filter are detailed in Figure 2. Each numbered callout refers to a corresponding numbered description found immediately below the picture. 3 2 5 1 4 Figure 2. C2C Side Panel Indicators 1 Wiring OK Status Indicator When it is on (lit) it indicates the receptacle the C2C is plugged into is live and wired properly.
4 Overload Status Indicator If illuminated, this LED indicates the C2C is overloaded. Unplug components until the light is extinguished. 5 Detachable AC Input Power Cords Use one of the supplied power cords to connect to the nearest properly rated AC receptacle. The power cords are only two (2) feet long, which makes them easy to hide. The power cord is detachable, which allows it to be easily replaced with an optional longer power cord (sold separately).
Outlet Panel This section describes outlet panel functionality. The outlet panel for the C2C Power Filter is shown in Figure 3. Outlet panel descriptions are provided immediately below Figure 3. Figure 3. C2C Outlet Panel AC-Powered Outlets The C2C Power Filter provides connections for two (2) ACpowered devices (TV/MONITOR/AUX). The isolated noise filter banks (INFBs) eliminate any EMI/RFI that can negatively impact sound and video quality.
Installation C2C installation consists of the following steps: 1. Apply power 2. Making connections Apply Power Prior to connecting equipment to the C2C Power Filter, ensure the unit is functioning by connecting the AC Power Cord (provided), shown as 5 in Figure 2. When power is applied to the unit, it will automatically power up, and the side panel LEDs will illuminate, indicating that the unit is receiving power. Making Connections Connect the equipment to the two outlets shown in Figure 3.
Technical Specifications The following table contains the specifications for the C2C Power Filters.
Troubleshooting This section describes possible causes and solutions for the following problems: • Unit will not turn on. • WIRING OK indicator LED is not illuminated. Unit will not turn on Probable Cause: Input power cord is not connected properly. Solution: Ensure the supplied power cord is connected securely at both ends. Probable Cause: No power or insufficient power at wall outlet.
WIRING OK indicator LED is not illuminated Probable Cause: There are three reasons why the WIRING OK LED would not be illuminated: 1. Reversed polarity exists at the wall outlet. 2. Neutral wire is overloaded. 3. Earth ground is missing at the wall outlet. Solution: Operating the unit under these conditions may affect its surge protection performance. Contact an electrician to inspect the building wiring, or your home wiring, to correct the problem.
-3047A 990-3047A 1/2010