Specification
22 apc.com
Models H10BLK H15BLK INWALLKIT-BLK INWALLKIT-WHT J10BLK
Input
Nominal voltage
120 Vac 120 Vac 120 Vac 120 Vac 120 Vac
Rated input current
12 A 12 A 15 A 15 A 12 A
Input circuit breaker rating
15 A 15 A 15 A 15 A 15 A
Output
Number of outlets (all outlets are surge 
protected, conditioned, regulated, and 
backed up by battery power)
12 12 2 2 12
Output voltage range while in 
voltage regulation mode (with factory 
default settings)
120 V ± 7% 120 V ± 7% N/A N/A 120 V ± 7%
Outlet type
NEMA 5–15R 
(Tested to UL 498)
NEMA 5–15R 
(Tested to UL 498)
NEMA 5–15R 
(Tested to UL 498)
NEMA 5–15R 
(Tested to UL 498)
NEMA 5–15R 
(Tested to UL 498)
Rated VA capacity
1,000 VA 1,440 VA N/A N/A 1,000 VA
Rated watt capacity (continuous)
1,000 W 1,440 VA N/A N/A 600W
Rated output current
12 A 12 A 15 A 15 A 9 A
Battery backup
Output voltage range while on battery
N/A N/A N/A N/A 120 V ± 7%
Battery quantity/type
N/A N/A N/A N/A APCRBC108
Typical recharge time to 90% capacity
N/A N/A N/A N/A 16hours
Battery service
N/A N/A N/A N/A User-replaceable, 
hot-swappable
Battery life
1
N/A N/A N/A N/A 3 – 5 years
Battery 
runtime
2
Internal batteries only
N/A N/A N/A N/A Half load 18.8 min/full 
load 6.4 min
Internal batteries and 1 SBATT
N/A N/A N/A N/A
N/A
Internal batteries and 2 SBATT
N/A N/A N/A N/A
N/A
Surge protection
Let-through voltage rating
3
< 40 V < 40 V N/A N/A < 85 V
Data line protection jacks
Coax
2 pair 2 pair + splitter N/A N/A 3 pair
Ethernet
N/A N/A N/A N/A N/A
Telephone/DSL
Same 1 line, 2 wire with splitter N/A N/A 1 line 2 wire
Physical
Communications and management
2 DC trigger jacks 2 DC trigger jacks N/A N/A USB port
Unit dimensions
17”W × 3.74”H × 9.5”D 17”W × 3.74”H × 9.5”D 9.5”W × 17.1”H × 1.7”D 9.5”W × 17.1”H × 1.7”D 5.25”W × 17.0”H × 
18.0”D
Unit weight
16.1 lbs/7.3 kg 16.7 lbs/7.6 kg 8.6 lbs/3.90 kg 8.6 lbs/3.90 kg 43.30 lbs/19.68 kg
Conformance
Safety agency approvals
UL, CSA, NOM, UL 1012, 
UL 1449, UL 498, UL 497A, 
CSA C22.2, FCC Part 15 
Class B, FCC Part 68
UL, CSA, NOM, UL 1012, 
UL 1449, UL 498, UL 497A, 
CSA C22.2, FCC Part 15 
Class B, FCC Part 68
cETLus per UL 1283 and 
UL 514D
cETLus per UL 1283 and 
UL 514D
CSA, FCC Part 15 
Class B, FCC Part 68, 
UL 1778, UL 498
Warranty
Lifetime equipment protection policy
4
$500,000 $750,000 Relevant power 
conditioner EPP prevails
Relevant power 
conditioner EPP prevails
Lifetime: $750,000
Product warranty
5 years 5 years Lifetime Lifetime 2 years repair 
or replace
1
 Depends on use and environment temperature. 
2
 Actual runtimes are determined by load, battery charge level, battery health, and quantity 
ofbatteries installed. 
3
 Let‑through voltage rating using a 6 kV Category A Ringwave (NM) per the ANSI C62.41 spec. 
4
 See user manual for details.