Information Sheet


Tel: 800 800 4APC – US & Canada
Tel: 401 789 0204 – World wide

APC North America
132 Fairgrounds Road
West Kingston RI 02892 USA
Call: 800 800 4APC
Fax: 401 789 3710

APC Ireland
Ballybrit Business Park
Galway, Ireland
Call: +35 391 702000
Fax: +35 391 756909

APC Australia
Level 13, The Denison
65 Berry Street
North Sydney, NSW2060
Call: +61 2 8923 9373

5301 Blue Lagoon Dr. Suite
#610, Miami FL 33126 USA
Call: 305 266 5005
Fax: 305 266 9695
Visit: www.apc.com
E-mail: apcinfo@apcc.com
Web Support: support.apcc.com
PowerFax
®
: 800-347-FAXX
APC’s quality
system is
certified by ISO
9001 standards
©2010 Schneider Electric Industries SAS, All Rights Reserved. Schneider Electric, APC, and APC AV are owned by Schneider Electric, or its affiliated companies in the United States and
other|countries. All other trademarks are property of their respective owners. Specifications are subject to change without notice. 996-4054b
Features and Specifications
C Type Power Conditioner
C2/C2C C5BLK C10BLK



Short-term increase
in RMS voltage levels

Dramatic and instantaneous
increase in voltage

Electromagnetic and
radio frequency
interference (EMI/RFI)


Start/stop of household appliances
(washing machine, AC, etc)
Lightning
Generated by appliances, HAM
radios, nearby radio stations,
and even AV equipment itself


N/A None If severe enough, can cause an
audible hum or buzzing sound


N/A None Visible lines of distortion
(“hum bar” distortion) possible


Stresses power supplies and/or
causes premature failure
Catastrophic failure N/A
Models
C2/C2C C5BLK C10BLK

Nominal Voltage 120 Vac 120 Vac 120 Vac
Rated Input Current 12Amps 12Amps 12Amps
Input Circuit Breaker Rating 15A 15A 15A

Number of Outlets (all outlets are surge protected,
conditioned, regulated, and backed up by battery power)
2 10 12
Output Voltage Range while in Voltage Regulation
mode (with factory default settings)
N/A N/A N/A
Outlet Type NEMA 5–15R (tested to UL498) NEMA 5–15R (tested to UL498) NEMA 5–15R (tested to UL498)
Rated VA Capacity N/A N/A N/A
Rated Watt Capacity (continuous) N/A N/A N/A
Rated Output Current 12A 12A 12A

Let-Through Voltage Rating <40V <40V <40V

Coax N/A 2 pair 3 pair
Ethernet N/A N/A 1 pair 10/100bT
Telephone/DSL N/A 1 line, 2 wire 1 line, 2 wire

Communications and Management None None 1 DC Trigger
Unit Dimensions 6.7”W × 3.7”H × 1.6”D 19.65”W × 5.22”H × 2.09”D 22.7”W × 6.5”H × 2.18”D
Unit Weight 1.5 lbs / .68 kg 5.1 lbs / 2.3 kg 6.71 lbs / 3.1 kg

Safety Agency Approvals
UL, CSA, UL1449, UL1283, FCC Part 68 Class B UL, cUL, NOM, UL1449, UL1363, UL498, UL497A, FCC
Part 15 Class B, FCC Part 68
UL, cUL, NOM, UL1449, UL1363, UL498,
UL497A, FCC Part 15 Class B, FCC Part 68

Lifetime Equipment Protection Policy $350,000 $350,000 $350,000
Product Warranty Lifetime Lifetime Lifetime