User Manual
LED
Condition
On
Off
Constant Tone
On
(Off during 4 beeps)
4 beeps repeated
every 30 seconds
Flashing Constant beeping
(every 1/2 second)
Constant tone
Off
Short beep every
4 seconds
Constant Tone
Audible Alarm
Long beep every
4 seconds
Status Indicators
On-line - The EasyUPS is supplying AC power to the
connected equipment
On Line Overload - The power being used by the connected
equipment has exceeded the capacity of the unit.
Disconnect some equipment.
Over-temperature - The unit is overheating and will operate
in AVR mode for 5 minutes. The Easy UPS will shut down if
the temperature is not lowered. Disconnect some of
the connected equipment.
On-Battery - The Easy UPS is supplying battery power.
Low Battery - The Easy UPS is supplying battery power and
the battery is near a total discharge state.
Bad Battery Detected - The battery needs to be charged,
or is at end of life.
Low Battery Shutdown - During On Battery operation
the battery power was almost completely exhausted, and the
Easy UPS is waiting for AC power to return to normal.
On Battery Overload - The connected equipment requires
more power than provided by the Easy UPS battery.
Unplug devices one at a time to remove overload.
If the problem is not corrected, contact SEIT Technical
Support
Charger Detected Fault - Easy UPS has an internal problem,
and is no longer powering the load.
Contact SEIT Technical Support
Over-temperature Protected - The Easy UPS has
overheated and has shut down. Unplug connected devices
one at a time or wait for a few hours for system to cool down.
Constant beeping
(every 1/2 second)
4
Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA
Operational Features
Automatic Voltage Regulation boosts/trims the AC voltage when it drops/exceeds levels.
This allows the equipment plugged into the unit to operate during low/high voltage conditions,
conserving the battery power in the event of a power cut.
The Easy UPS will switch to battery power if the input voltage level becomes too low/high for the
Automatic Voltage Regulation to compensate, or if the AC power is distorted.
Automatic Voltage Regulation (AVR)