User Manual

Back-UPS BR900G-RS Installation and Operation6
Alerts and System Events
Audible Alerts
Events Icons
System Events
Four Beeps Every 30 Seconds Back-UPS is running on battery. You should consider saving any work in progress.
Continuous Beeping Low battery condition and battery run-time is very low. Promptly save any work in progress,
exit all open applications, and shut down the operating system.
Continuous tone Battery Backup outputs are overloaded.
Chirps for 1 Minute every 5 hours Battery is not able to pass the automatic diagnostic test and should be replaced.
If these icons are
illuminated... This may be the problem.
The Back-UPS is operating on A/C power, but is overloaded. Disconnect one of the devices connected
to the Back-UPS. If the Overload icon stops flashing, the Back-UPS is no longer overloaded and will
continue to operate normally.
The Back-UPS is operating on battery power, but is overloaded. Disconnect one of the devices
connected to the Back-UPS. If the Overload icon stops flashing, the Back-UPS is no longer overloaded
and will continue to operate normally.
The Back-UPS is operating on A/C power, but the battery is not functioning properly.
Contact APC Customer Service to order a replacement battery.
The Back-UPS is operating on battery power and the battery power is getting low. Shut down all
connected equipment to avoid losing unsaved data. When possible, connect the Back-UPS to A/C
power to recharge the battery.
F01
On-Battery Overload Turn the Back-UPS off. Disconnect non-essential
equipment from the Battery Backup outlets and then
turn Back-UPS on.
F02
On-Battery Output Short Turn the Back-UPS off. Disconnect non-essential
equipment from the Battery Backup outlets and then
turn Back-UPS on.
F03
On-Battery Xcap Overload
Events F03-F09 are not user serviceable. Contact
APC Technical Support for assistance.
F04
Clamp Short
F05
Charge Status
F06
Relay Welding
F07
Temperature
F08
Fan Condition
F09
Internal Event