- Safety and General Information
- Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage.
- SAVE THESE INSTRUCTIONS - This section contains important instructions that should be followed during installation and maintenance of the UPS and batteries.
- Inventory
- Connect the Battery
- Specifications
- Connect Equipment
- Turn On the Back-UPS
- Turn Off the Back-UPS
- Quick Mute
- On Battery Indicator Modes
- Voltage Sensitivity Adjustment (optional)
- Status Indicators
- Troubleshooting
- Wall Mount Installation
- Service
- Battery Replacement
- Warranty
- Register your product on-line. http://warranty.apc.com
- APC by Schneider Electric IT Customer Support Worldwide
- EMC Compliance
- WARNING! Handling Safety
- WARNING! Deenergize Safety
- WARNING! Electrical Safety
- WARNING! Battery Safety
- User Manual Back-UPS™ BE425M/425M-LM, BN450M/450M-CA
- Safety Information - SAVE THIS GUIDE
Back-UPS BE425M/425M-LM, BN450M/450M-CA
7
Wall Mount Installation
• Horizontal installation, use 2 screws 7.63” (194 mm) apart.
• Allow 5/16” (8 mm), of the screw to protrude from the wall.
Service
If the unit requires service, do not return it to the dealer. Follow these steps:
1. Review the Troubleshooting section of the manual to eliminate common problems.
2. If the problem persists, contact Schneider Electric IT (SEIT) Customer Support
through the APC by Schneider Electric Web site, www.apc.com.
a. Note the model number and serial number and the date of purchase. The model
and serial numbers are located on the rear panel of the unit and are available
through the LCD display on select models.
b. Call SEIT Customer Support and a technician will attempt to solve the
problem over the phone. If this is not possible, the technician will issue a
Returned Material Authorization Number (RMA#).
c. If the unit is under warranty, the repairs are free.
d. Service procedures and returns may vary internationally. Refer to the APC by
Schneider Electric Web site for country specific instructions.
3. Pack the unit in the original packaging whenever possible to avoid damage in
transit. Never use foam beads for packaging. Damage sustained in transit is not
covered under warranty.
4. Always DISCONNECT THE UPS BATTERIES before shipping. The United
States Department of Transportation (DOT), and the International Air
Transport Association (IATA) regulations require that UPS batteries be
disconnected before shipping. The internal batteries may remain in the UPS.
5. Write the RMA# provided by Customer Support on the outside of the package.
6. Return the unit by insured, pre-paid carrier to the address provided by Customer
Support.