User's Manual
Table Of Contents
- Safety and General Information
- Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage.
- SAVE THESE INSTRUCTIONS - This section contains important instructions that should be followed during installation and maintenance of the UPS and batteries.
- Inventory
- Connect the Battery
- Specifications
- Connect Equipment
- Turn On the Back-UPS
- Turn Off the Back-UPS
- Quick Mute
- On Battery Indicator Modes
- Voltage Sensitivity Adjustment (optional)
- Status Indicators
- Troubleshooting
- Wall Mount Installation
- Service
- Battery Replacement
- Warranty
- Register your product on-line. http://warranty.apc.com
- APC by Schneider Electric IT Customer Support Worldwide
- EMC Compliance
- WARNING! Handling Safety
- WARNING! Deenergize Safety
- WARNING! Electrical Safety
- WARNING! Battery Safety
- User Manual Back-UPS™ BE425M/425M-LM, BN450M/450M-CA
- Safety Information - SAVE THIS GUIDE
Back-UPS BE425M/425M-LM, BN450M/450M-CA
3
Connect Equipment
.
Turn On the Back-UPS
Press the POWER button. It will illuminate green and a single short beep indicating that
the Back-UPS is on and providing protection for connected equipment.
The Back-UPS battery will charge regardless of whether the Back-UPS is switched on or
off as long as it is connected to AC power. The UPS will have full runtime capability
after the initial 24-hour charging period, connected to AC power.
If the red Building Wiring Fault indicator (located on the end near the power cord) is lit,
your building wiring may present a shock hazard that should be corrected by a qualified
electrician.
Model
BE425M / BE425M-LM
BN450M / BN450M-CA
Physical
Net Weight 5.7 lb (2.6 kg)
Dimensions
LxWxH
9.98 in x 4.13 in x 5.51 in
25.35 cm x 10.5 cm x 14.02 cm
Operating Temperature 32º F to 104º F (0º C to 40º C)
Storage Temperature -4º F to 122º F (–20º C to 50º C)
Operating Relative Humidity 0 to 95% non-condensing humidity
Operating Elevation 0 to 10,000 ft (0 to 3000 m)
Feature Function Suggested Use
Battery Backup +
Surge Protection
Outlets
• Receive power from the battery for a
limited period of time when a power
outage, or brownout condition
occurs.
• Provide protection from power
surges or spikes.
Connect a computer, monitor
and other critical peripheral
devices that need to remain on
during power outages or AC
problems.
Surge Protection
Outlets
• Provide protection from power
surges or spikes.
Connect non-critical
peripheral devices (such as
printer, scanner, etc.) that do
not need to remain on during
power outages or AC
problems.
Battery Backup + Surge
Protection Outlets
Surge Protection
Outlets
bu461a
POWER
Button
Back-UPS 450
Surge
bu460a
Building
Wiring
Fault
AC Power
Inlet
Circuit
Breaker