User's Manual
Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 / M2-CA
4
Operation
Power Saving Display 
The display interface can be configured to be continuously illuminated, or to save 
energy, it can be configured to darken after a period of inactivity.
1. Full Time Mode: Press and hold DISPLAY for two seconds. The display will 
illuminate and the Back-UPS will beep to confirm the Full Time mode. 
2. Power Saving Mode: Press and hold DISPLAY for two seconds. The display will 
darken and the Back-UPS will beep to confirm the Power Saving mode. While in 
Power Saving Mode, the display will illuminate if a button is pressed, it then 
darkens after 60 seconds of no activity. 
Unit sensitivity
Adjust the sensitivity of the Back-UPS to control when it will switch to battery power; 
the higher the sensitivity, the more often the Back-UPS will switch to battery power. 
1. Ensure the Back-UPS is connected to AC power, but is OFF.
2. Press and hold the POWER button for six seconds. The LOAD CAPACITY bar will 
flash on and off, indicating that the Back-UPS is in programming mode.
3. Press POWER again to rotate through the menu options. Stop at selected 
sensitivity. The Back-UPS will beep to confirm the selection.
Generator Sensitivity Default Sensitive Loads
Low sensitivity Medium sensitivity (Default) High sensitivity
78-142 Vac 88-139 Vac 88-136 Vac
Input voltage is extremely low 
or high. (Not recommended for 
computer loads.)
The Back-UPS frequently 
switches to battery power.
The connected equipment is 
sensitive to voltage 
fluctuations.