User Manual

Back-UPS BE650G2-RS/BE850G2-RS8
Installation
Note: To reduce electronic waste and protect the environment, USB cables are
no longer shipped in every box. Order the cable free of charge at
https://www.apc.com/usbcable.
Use the USB cable to connect the Data port on the UPS to the USB port on
your computer. Download PowerChute
Personal Edition Software from
www.apc.com/pcpe. Select the appropriate operating system and follow
directions to download the software.
Status Indicators
Visual indicator
Audible
indicator Condition
Audible indicator
terminates
Power on/off LED
illuminates green
None Power On - The Back-UPS is
supplying utility power to the
connected equipment.
Not applicable.
Power on/off LED
flashes green twice
every 2 seconds
4 beeps
approx.
every 40
seconds.
On Battery - The Back-UPS is
supplying battery power to the
battery backup outlets.
Beeping stops when
utility power is
restored or the
Back-UPS is turned
off.
Power on/off LED
flashes green in quick
succession.
Rapid
beeping
(1 beep
every 0.5
second)
Low Battery notification The
Back-UPS is supplying battery
power to the battery backup
outlets and the battery is
nearing a total discharge state.
Power on/off LED
flashes green in quick
succession.
1 beep
every 4
seconds
Low Battery shutdown - The
battery has been completely
discharged while the
Back-UPS is on battery, the
Back-UPS will shutdown.
Beeping stops when
utility power is
restored or the
Back-UPS is turned
off.
None Sleep Mode - The Back-UPS
has shutdown and will return to
normal operation once utility
power is restored.
Not applicable.
Power on/off LED
flashes red and Battery
status LED flashes
green in quick
succession.
Constant
tone
Battery disconnected. Back-UPS is turned
off.
Power on/off LED
flashes green and red
alternately
Constant
tone
Replace battery - The battery
needs to be charged or replaced.
Back-UPS is turned
off.